daily run output not parsing smartd output correctly

I’ve noticed that the smartd output has changed. It’s not parsing the results correctly.

Security check:
   (output mailed separately)

Checking for denied zone transfers (AXFR and IXFR):

Scrubbing of zfs pools:
  skipping scrubbing of pool 'system':
     last scrubbing is 3 days ago, threshold is set to 7 days

Backing up pkgng database:

SMART status:
Checking health of /dev/ada0: OK
Checking health of /dev/ada1: OK
Checking health of /dev/da0: === START OF INFORMATION SECTION ===
Model Family:     Toshiba 3.5" HDD DT01ACA...
Device Model:     TOSHIBA DT01ACA300
Serial Number:    Z2T5TSSAS
LU WWN Device Id: 5 000039 ff4c2a2d3
Firmware Version: MX6OABB0
User Capacity:    3,000,592,982,016 bytes [3.00 TB]
Sector Sizes:     512 bytes logical, 4096 bytes physical
Rotation Rate:    7200 rpm
Device is:        In smartctl database [for details use: -P show]
ATA Version is:   ATA8-ACS T13/1699-D revision 4
SATA Version is:  SATA 3.0, 6.0 Gb/s (current: 6.0 Gb/s)
Local Time is:    Wed Mar 12 03:16:16 2014 UTC
SMART support is: Available - device has SMART capability.
SMART support is: Enabled

=== START OF READ SMART DATA SECTION ===
SMART STATUS RETURN: incomplete response, ATA output registers missing
SMART overall-health self-assessment test result: PASSED
Warning: This result is based on an Attribute check.

General SMART Values:
Offline data collection status:  (0x84)	Offline data collection activity
					was suspended by an interrupting command from host.
					Auto Offline Data Collection: Enabled.
Self-test execution status:      (   0)	The previous self-test routine completed
					without error or no self-test has ever 
					been run.
Total time to complete Offline 
data collection: 		(23943) seconds.
Offline data collection
capabilities: 			 (0x5b) SMART execute Offline immediate.
					Auto Offline data collection on/off support.
					Suspend Offline collection upon new
					command.
					Offline surface scan supported.
					Self-test supported.
					No Conveyance Self-test supported.
					Selective Self-test supported.
SMART capabilities:            (0x0003)	Saves SMART data before entering
					power-saving mode.
					Supports SMART auto save timer.
Error logging capability:        (0x01)	Error logging supported.
					General Purpose Logging supported.
Short self-test routine 
recommended polling time: 	 (   1) minutes.
Extended self-test routine
recommended polling time: 	 ( 399) minutes.
SCT capabilities: 	       (0x003d)	SCT Status supported.
					SCT Error Recovery Control supported.
					SCT Feature Control supported.
					SCT Data Table supported.

SMART Attributes Data Structure revision number: 16
Vendor Specific SMART Attributes with Thresholds:
ID# ATTRIBUTE_NAME          FLAG     VALUE WORST THRESH TYPE      UPDATED  WHEN_FAILED RAW_VALUE
 1 Raw_Read_Error_Rate     0x000b   100   100   016    Pre-fail  Always       -       0
 2 Throughput_Performance  0x0005   138   138   054    Pre-fail  Offline      -       74
 3 Spin_Up_Time            0x0007   145   145   024    Pre-fail  Always       -       375 (Average 413)
 4 Start_Stop_Count        0x0012   100   100   000    Old_age   Always       -       61
 5 Reallocated_Sector_Ct   0x0033   100   100   005    Pre-fail  Always       -       0
 7 Seek_Error_Rate         0x000b   100   100   067    Pre-fail  Always       -       0
 8 Seek_Time_Performance   0x0005   124   124   020    Pre-fail  Offline      -       33
 9 Power_On_Hours          0x0012   099   099   000    Old_age   Always       -       7061
10 Spin_Retry_Count        0x0013   100   100   060    Pre-fail  Always       -       0
12 Power_Cycle_Count       0x0032   100   100   000    Old_age   Always       -       61
192 Power-Off_Retract_Count 0x0032   100   100   000    Old_age   Always       -       95
193 Load_Cycle_Count        0x0012   100   100   000    Old_age   Always       -       95
194 Temperature_Celsius     0x0002   187   187   000    Old_age   Always       -       32 (Min/Max 13/43)
196 Reallocated_Event_Count 0x0032   100   100   000    Old_age   Always       -       0
197 Current_Pending_Sector  0x0022   100   100   000    Old_age   Always       -       0
198 Offline_Uncorrectable   0x0008   100   100   000    Old_age   Offline      -       0
199 UDMA_CRC_Error_Count    0x000a   200   200   000    Old_age   Always       -       0

SMART Error Log Version: 1
No Errors Logged

SMART Self-test log structure revision number 1
No self-tests have been logged.  [To run self-tests, use: smartctl -t]


SMART Selective self-test log data structure revision number 1
SPAN  MIN_LBA  MAX_LBA  CURRENT_TEST_STATUS
   1        0        0  Not_testing
   2        0        0  Not_testing
   3        0        0  Not_testing
   4        0        0  Not_testing
   5        0        0  Not_testing
Selective self-test flags (0x0):
 After scanning selected spans, do NOT read-scan remainder of disk.
If Selective self-test is pending on power-up, resume after 0 minute delay.

Checking health of /dev/da1: === START OF INFORMATION SECTION ===
Model Family:     Toshiba 3.5" HDD DT01ACA...
Device Model:     TOSHIBA DT01ACA300
Serial Number:    Z2U658MGS
LU WWN Device Id: 5 000039 ff4c2ce0a
Firmware Version: MX6OABB0
User Capacity:    3,000,592,982,016 bytes [3.00 TB]
Sector Sizes:     512 bytes logical, 4096 bytes physical
Rotation Rate:    7200 rpm
Device is:        In smartctl database [for details use: -P show]
ATA Version is:   ATA8-ACS T13/1699-D revision 4
SATA Version is:  SATA 3.0, 6.0 Gb/s (current: 6.0 Gb/s)
Local Time is:    Wed Mar 12 03:16:18 2014 UTC
SMART support is: Available - device has SMART capability.
SMART support is: Enabled

=== START OF READ SMART DATA SECTION ===
SMART STATUS RETURN: incomplete response, ATA output registers missing
SMART overall-health self-assessment test result: PASSED
Warning: This result is based on an Attribute check.

General SMART Values:
Offline data collection status:  (0x84)	Offline data collection activity
					was suspended by an interrupting command from host.
					Auto Offline Data Collection: Enabled.
Self-test execution status:      (   0)	The previous self-test routine completed
					without error or no self-test has ever 
					been run.
Total time to complete Offline 
data collection: 		(22652) seconds.
Offline data collection
capabilities: 			 (0x5b) SMART execute Offline immediate.
					Auto Offline data collection on/off support.
					Suspend Offline collection upon new
					command.
					Offline surface scan supported.
					Self-test supported.
					No Conveyance Self-test supported.
					Selective Self-test supported.
SMART capabilities:            (0x0003)	Saves SMART data before entering
					power-saving mode.
					Supports SMART auto save timer.
Error logging capability:        (0x01)	Error logging supported.
					General Purpose Logging supported.
Short self-test routine 
recommended polling time: 	 (   1) minutes.
Extended self-test routine
recommended polling time: 	 ( 378) minutes.
SCT capabilities: 	       (0x003d)	SCT Status supported.
					SCT Error Recovery Control supported.
					SCT Feature Control supported.
					SCT Data Table supported.

SMART Attributes Data Structure revision number: 16
Vendor Specific SMART Attributes with Thresholds:
ID# ATTRIBUTE_NAME          FLAG     VALUE WORST THRESH TYPE      UPDATED  WHEN_FAILED RAW_VALUE
 1 Raw_Read_Error_Rate     0x000b   100   100   016    Pre-fail  Always       -       0
 2 Throughput_Performance  0x0005   139   139   054    Pre-fail  Offline      -       71
 3 Spin_Up_Time            0x0007   143   143   024    Pre-fail  Always       -       381 (Average 421)
 4 Start_Stop_Count        0x0012   100   100   000    Old_age   Always       -       42
 5 Reallocated_Sector_Ct   0x0033   100   100   005    Pre-fail  Always       -       0
 7 Seek_Error_Rate         0x000b   100   100   067    Pre-fail  Always       -       0
 8 Seek_Time_Performance   0x0005   124   124   020    Pre-fail  Offline      -       33
 9 Power_On_Hours          0x0012   100   100   000    Old_age   Always       -       6775
10 Spin_Retry_Count        0x0013   100   100   060    Pre-fail  Always       -       0
12 Power_Cycle_Count       0x0032   100   100   000    Old_age   Always       -       42
192 Power-Off_Retract_Count 0x0032   100   100   000    Old_age   Always       -       69
193 Load_Cycle_Count        0x0012   100   100   000    Old_age   Always       -       69
194 Temperature_Celsius     0x0002   176   176   000    Old_age   Always       -       34 (Min/Max 16/44)
196 Reallocated_Event_Count 0x0032   100   100   000    Old_age   Always       -       0
197 Current_Pending_Sector  0x0022   100   100   000    Old_age   Always       -       0
198 Offline_Uncorrectable   0x0008   100   100   000    Old_age   Offline      -       0
199 UDMA_CRC_Error_Count    0x000a   200   200   000    Old_age   Always       -       0

SMART Error Log Version: 1
No Errors Logged

SMART Self-test log structure revision number 1
No self-tests have been logged.  [To run self-tests, use: smartctl -t]


SMART Selective self-test log data structure revision number 1
SPAN  MIN_LBA  MAX_LBA  CURRENT_TEST_STATUS
   1        0        0  Not_testing
   2        0        0  Not_testing
   3        0        0  Not_testing
   4        0        0  Not_testing
   5        0        0  Not_testing
Selective self-test flags (0x0):
 After scanning selected spans, do NOT read-scan remainder of disk.
If Selective self-test is pending on power-up, resume after 0 minute delay.


-- End of daily output --