GEOM Watch sent me an email this morning:
The status of GEOM MIRROR/gm0 has changed from COMPLETE to DEGRADED. The following components have been lost: ad6 Remaining components: ad3
Here’s the smartctl output:
[dan@ngaio:~] $ sudo smartctl -a -i /dev/ad6
smartctl 5.43 2012-06-30 r3573 [FreeBSD 8.2-STABLE i386] (local build)
Copyright (C) 2002-12 by Bruce Allen, http://smartmontools.sourceforge.net
=== START OF INFORMATION SECTION ===
Model Family: Maxtor DiamondMax Plus 9
Device Model: Maxtor 6Y120M0
Serial Number: Y3PJP7VE
Firmware Version: YAR51HW0
User Capacity: 122,942,324,736 bytes [122 GB]
Sector Size: 512 bytes logical/physical
Device is: In smartctl database [for details use: -P show]
ATA Version is: 7
ATA Standard is: ATA/ATAPI-7 T13 1532D revision 0
Local Time is: Fri Feb 1 12:11:43 2013 UTC
SMART support is: Available - device has SMART capability.
SMART support is: Enabled
=== START OF READ SMART DATA SECTION ===
SMART overall-health self-assessment test result: PASSED
General SMART Values:
Offline data collection status: (0x80) Offline data collection activity
was never started.
Auto Offline Data Collection: Enabled.
Self-test execution status: ( 0) The previous self-test routine completed
without error or no self-test has ever
been run.
Total time to complete Offline
data collection: ( 242) seconds.
Offline data collection
capabilities: (0x5b) SMART execute Offline immediate.
Auto Offline data collection on/off support.
Suspend Offline collection upon new
command.
Offline surface scan supported.
Self-test supported.
No Conveyance Self-test supported.
Selective Self-test supported.
SMART capabilities: (0x0003) Saves SMART data before entering
power-saving mode.
Supports SMART auto save timer.
Error logging capability: (0x01) Error logging supported.
No General Purpose Logging support.
Short self-test routine
recommended polling time: ( 2) minutes.
Extended self-test routine
recommended polling time: ( 54) minutes.
SMART Attributes Data Structure revision number: 16
Vendor Specific SMART Attributes with Thresholds:
ID# ATTRIBUTE_NAME FLAG VALUE WORST THRESH TYPE UPDATED WHEN_FAILED RAW_VALUE
3 Spin_Up_Time 0x0027 207 205 063 Pre-fail Always - 12278
4 Start_Stop_Count 0x0032 253 253 000 Old_age Always - 64
5 Reallocated_Sector_Ct 0x0033 253 253 063 Pre-fail Always - 1
6 Read_Channel_Margin 0x0001 253 253 100 Pre-fail Offline - 0
7 Seek_Error_Rate 0x000a 253 252 000 Old_age Always - 0
8 Seek_Time_Performance 0x0027 250 239 187 Pre-fail Always - 38830
9 Power_On_Minutes 0x0032 162 162 000 Old_age Always - 159h+37m
10 Spin_Retry_Count 0x002b 253 252 157 Pre-fail Always - 0
11 Calibration_Retry_Count 0x002b 253 252 223 Pre-fail Always - 0
12 Power_Cycle_Count 0x0032 253 253 000 Old_age Always - 256
192 Power-Off_Retract_Count 0x0032 253 253 000 Old_age Always - 0
193 Load_Cycle_Count 0x0032 253 253 000 Old_age Always - 0
194 Temperature_Celsius 0x0032 253 253 000 Old_age Always - 50
195 Hardware_ECC_Recovered 0x000a 253 252 000 Old_age Always - 12707
196 Reallocated_Event_Count 0x0008 253 253 000 Old_age Offline - 0
197 Current_Pending_Sector 0x0008 253 253 000 Old_age Offline - 0
198 Offline_Uncorrectable 0x0008 253 253 000 Old_age Offline - 0
199 UDMA_CRC_Error_Count 0x0008 199 199 000 Old_age Offline - 0
200 Multi_Zone_Error_Rate 0x000a 253 252 000 Old_age Always - 0
201 Soft_Read_Error_Rate 0x000a 253 243 000 Old_age Always - 124
202 Data_Address_Mark_Errs 0x000a 253 250 000 Old_age Always - 0
203 Run_Out_Cancel 0x000b 253 252 180 Pre-fail Always - 44
204 Soft_ECC_Correction 0x000a 253 252 000 Old_age Always - 0
205 Thermal_Asperity_Rate 0x000a 253 252 000 Old_age Always - 0
207 Spin_High_Current 0x002a 253 252 000 Old_age Always - 0
208 Spin_Buzz 0x002a 253 252 000 Old_age Always - 0
209 Offline_Seek_Performnce 0x0024 197 192 000 Old_age Offline - 0
99 Unknown_Attribute 0x0004 253 253 000 Old_age Offline - 0
100 Unknown_Attribute 0x0004 253 253 000 Old_age Offline - 0
101 Unknown_Attribute 0x0004 253 253 000 Old_age Offline - 0
SMART Error Log Version: 1
ATA Error Count: 2
CR = Command Register [HEX]
FR = Features Register [HEX]
SC = Sector Count Register [HEX]
SN = Sector Number Register [HEX]
CL = Cylinder Low Register [HEX]
CH = Cylinder High Register [HEX]
DH = Device/Head Register [HEX]
DC = Device Command Register [HEX]
ER = Error register [HEX]
ST = Status register [HEX]
Powered_Up_Time is measured from power on, and printed as
DDd+hh:mm:SS.sss where DD=days, hh=hours, mm=minutes,
SS=sec, and sss=millisec. It "wraps" after 49.710 days.
Error 2 occurred at disk power-on lifetime: 27812 hours (1158 days + 20 hours)
When the command that caused the error occurred, the device was in an unknown state.
After command completion occurred, registers were:
ER ST SC SN CL CH DH
-- -- -- -- -- -- --
84 51 00 7f b4 df e7 Error: ICRC, ABRT at LBA = 0x07dfb47f = 132101247
Commands leading to the command that caused the error were:
CR FR SC SN CL CH DH DC Powered_Up_Time Command/Feature_Name
-- -- -- -- -- -- -- -- ---------------- --------------------
c8 00 80 7f b4 df e7 00 01:05:17.504 READ DMA
c8 00 00 00 75 25 e2 00 01:05:17.504 READ DMA
c8 00 00 00 74 25 e2 00 01:05:17.472 READ DMA
c8 00 80 ff b3 df e7 00 01:05:17.472 READ DMA
c8 00 00 00 73 25 e2 00 01:05:17.456 READ DMA
Error 1 occurred at disk power-on lifetime: 27812 hours (1158 days + 20 hours)
When the command that caused the error occurred, the device was in an unknown state.
After command completion occurred, registers were:
ER ST SC SN CL CH DH
-- -- -- -- -- -- --
84 51 00 00 c6 b7 e1 Error: ICRC, ABRT at LBA = 0x01b7c600 = 28820992
Commands leading to the command that caused the error were:
CR FR SC SN CL CH DH DC Powered_Up_Time Command/Feature_Name
-- -- -- -- -- -- -- -- ---------------- --------------------
c8 00 00 00 c6 b7 e1 00 00:52:57.152 READ DMA
c8 00 00 00 c5 b7 e1 00 00:52:57.136 READ DMA
c8 00 04 5b 05 a9 e5 00 00:52:57.120 READ DMA
c8 00 00 00 c4 b7 e1 00 00:52:57.120 READ DMA
c8 00 04 d3 04 a9 e5 00 00:52:57.120 READ DMA
SMART Self-test log structure revision number 1
Num Test_Description Status Remaining LifeTime(hours) LBA_of_first_error
# 1 Extended offline Completed without error 00% 29049 -
# 2 Extended offline Completed without error 00% 6293 -
# 3 Extended offline Completed without error 00% 6291 -
# 4 Short offline Completed without error 00% 6291 -
SMART Selective self-test log data structure revision number 1
SPAN MIN_LBA MAX_LBA CURRENT_TEST_STATUS
1 0 0 Not_testing
2 0 0 Not_testing
3 0 0 Not_testing
4 0 0 Not_testing
5 0 0 Not_testing
Selective self-test flags (0x0):
After scanning selected spans, do NOT read-scan remainder of disk.
If Selective self-test is pending on power-up, resume after 0 minute delay.
[dan@ngaio:~] $












Comments from IRC:
drive has one bad sector, now it remapped. (Reallocated_Sector_Ct. ID #5)
Hardware_ECC_Recovered could be also sign of overheating though.
and probably Soft_Read_Error_Rate
I will swap out this drive, hopefully today. :)
FYI, this drive had a loose cable. I replaced it with a better connection.