hardware

Preparing the Dell R720 for ZFS

I have obtained a Dell R720 containing 10 x 400GB SSDs. The drives are connected to a RAID controller (H710P) which cannot do JBOD / IT mode. This means the drives are effectively hidden from ZFS, which is never good. In this post: FreeBSD 12.0 ZFS Dell R720 SAS 9207-8i This post describes past work and future plans for this server as I get it ready to be a general purpose server running

Preparing the Dell R720 for ZFS Read More »

Updating firmware etc on a Dell R720

See also: Updating firmware etc on a Dell R730 I started writing this blog about a month ago. Last night, I did the firmware upgrade completely forgetting I had this draft post in my blog. Instead of reading this, I wound up doing something very similar, and pretty much lived tweeted it. After upgrading the IDRAC to the latest, I then went into the LifeCycle Controller and upgraded nearly all the things. However,

Updating firmware etc on a Dell R720 Read More »

3Ware device degraded

On supernews a drive acted up over night. The main purpose of this post is for me to record the information. You might not find much useful here. The host is running FreeBSD 12 and is a FreshPorts development box. I saw this error in the logs: smart emailed me because I set that up some time ago. The email looked like this: This message was generated by the smartd daemon running on:

3Ware device degraded Read More »

Replacing both drives in a zpool mirror

As previously mentioned, zuul has new drives. It is now time to replace the existing drives with the new drives. I will do this one at a time. Replace. Wait for resilver. At no time will the mirror be degraded (as would be the case if we removed a drive and mirrored). In this approach, we will mirror one of the drives to a new drive, and zfs will automatically remove the old

Replacing both drives in a zpool mirror Read More »

new drives for zuul

I have two new drives for zuul. I’ll start adding them into the zpool soon. For now, here is the smarctl output for the new drives. I’ll start some tests on them soon. By new, I mean new to this host. The drives have 17,000 hours on them. [dan@zuul:~] $ sudo smartctl -a /dev/ada2 smartctl 7.0 2018-12-30 r4883 [FreeBSD 12.0-RELEASE-p7 amd64] (local build) Copyright (C) 2002-18, Bruce Allen, Christian Franke, www.smartmontools.org === START

new drives for zuul Read More »

slocum – the new : assembly details

This covers the facts regarding the list of things to do on Server Build Saturday. The slocum – the new hardware changes occurred on 2 February 2019, with the help of a guy I’ve known since my early days in PA. jb33z did the heavy lifting, both of the chassis and of the HDD. He moved all the HDD from the old server to the new server. I did the SSDs, which were

slocum – the new : assembly details Read More »

slocum – the new

This post has been replaced by a new one. For reference, the previous post on this server is still available. This server was upgraded on Feb 2 2019. Only the storage persisted. Everything else was upgraded. The hardware M/B – Supermicro X9DRE-TF+ RAM – 128GB composed of 8x 16GB DDR3 1600Mhz 21300 ECC/REG CPU – 2x E5-2620v2 – Intel Six Core 2.10Ghz Xeon 15MB cache 7.2 GT/s QPI (80W) chassis – SC846E16-R1200B SAS9300-8i

slocum – the new Read More »

Server build Saturday!

Tomorrow I’ll be doing some server and rack work. I’ll be moving one system into a new chassis, combining two desktops into the old chassis, and putting both chassis back into the rack. There are a bunch of steps here and I want to write them down so they all get done. These steps were completed last night: Remove tape01 and tape02 from the rack. Remove the shelf from the rack which held

Server build Saturday! Read More »

Scroll to Top